Merge lubricant liquid from the transfer case.
Remove forward section of system of production of the fulfilled gases and the thermofilter.
Remove the forward driveshaft (see Removal and installation of driveshafts).
|
By means of a special key release a lock-nut of a connecting flange.
|
|
|
The lock-nut is subject to replacement without fail. |
|
Mark with paint the provision of a connecting flange of rather carving pin.
|
|
Remove a connecting flange by means of a stripper.
|
|
Having used special adaptation take an epiploon from a forward casing.
|
|
Establish a new epiploon, previously having greased its sealing sponges with universal lubricant.
Establish a connecting flange.
|
Tighten a lock-nut of a connecting flange with the required effort.
|
|
Install the driveshaft.
Installation of the remained components is made as it should be, the return to an order of their dismantle.
|